Keyword: ECRIS
Paper Title Other Keywords Page
MO2C3 Status and Perspective of Electron Cyclotron Resonance Based Charge Breeders ECR, plasma, electron, injection 6
 
  • J. Angot, M.A. Baylac, M. Migliore, T. Thuillier
    LPSC, Grenoble Cedex, France
  • O.A. Tarvainen
    STFC/RAL/ISIS, Chilton, Didcot, Oxon, United Kingdom
 
  Since their invention in the late 1990s, Electron Cyclotron Resonance (ECR) based Charge Breeders (CB) have been used in several Isotope Separation On Line (ISOL) facilities to study radioactive ions. Many developments were carried out on these devices to enhance their performances and improve the knowledge on the ECR charge breeding process in laboratories worldwide. At LPSC, recent experiments in pulse mode were carried out to estimate plasma parameters such as the ionisation, charge exchange and confinement times, providing indications on the high charge state ions confinement. A new model of the 1+ beam capture was also proposed and experimentally verified by studying the stopping of injected ions of different masses. Present ECR charge breeder optimum efficiencies vary from 10 to 20% depending on the ion species and the facilities specifications. The total efficiency ranges from 35 to 90% and the charge breeding time from 10 to 25 ms/q. Electron Beam Ion Source (EBIS) is an alternate CB technology with lower contamination yield, yet limited injection flux capability. ECR CB sustains a higher 1+ beam intensity acceptance and its prospects to improve the efficiency, charge breeding time and beam purity are identified.  
slides icon Slides MO2C3 [1.969 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-HIAT2022-MO2C3  
About • Received ※ 21 June 2022 — Revised ※ 30 June 2022 — Accepted ※ 01 July 2022 — Issue date ※ 10 August 2022
Cite • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)